LLW & greater than Class C waste
LLW waste is measured using a range of techniques depending on the volume and homogeneity of the waste. ANTECH provides a range of options for LLW measurement, which range from far field to segmented. Shielding is sometimes included in measurement instruments to reduce background radiation. Low Level Waste (LLW) upper thresholds vary.
UK – LLW upper thresholds correspond to:
- 12,000 Bq/g (324 nCi/g) for waste with beta-gamma activity
- 4,000 Bq/g (108 nCi/g) for waste with alpha activity
US – The upper threshold for LLW waste with alpha activity is:
- 100 nCi/g (3,700 Bq/g)
NOTE: In the USA, Class C LLW represents waste with higher beta-gamma activity and is generally equivalent to UK ILW with higher beta-gamma activity.

01 Low Resolution Drum Gamma Scanner, G3410-200
Environmental Monitoring, Exempt waste & VLLW, Gamma, Gamma ray Waste Assay, LLW & greater than Class C waste
The ANTECH Model G3410-200 LRDGS is a transportable Low Resolution Gamma Scanner for the characterisation and measurement of 200 L drums of waste.

02 EMBASSY (Excavator Mounted Bucket Assay System) G3102-4216
Environmental Monitoring, Exempt waste & VLLW, Gamma, Gamma ray Waste Assay, LLW & greater than Class C waste, Mobile In-Situ Measurement Laboratories, Radiation Detection, Radioactive Waste Measurement, Radioactive Waste Measurement
The ANTECH excavator mounted bucket assay system (EMBASSY) model G3102-4216 is a system designed to measure the radioactive contents of an excavator bucket.

03 Wide Range Segmented Gamma Scanner, G3250-220
Exempt waste & VLLW, Gamma, Gamma ray Waste Assay, ILW & high activity waste, LLW & greater than Class C waste, Plutonium & Uranium waste, TRU waste & ILW
The ANTECH G3250-220 Wide Range Segmented Gamma Scanner (WR-SGS) builds on the segmented gamma scanning technique to measure the radionuclide content of waste drums.

07 In-Situ Mobile Assay of Gamma Equipment (IMAGE)
Gamma, Gamma ray Waste Assay, ILW & high activity waste, LLW & greater than Class C waste, Mobile In-Situ Measurement Laboratories
The ANTECH IMAGE is a suite of measurement service equipment used for portable assay of all types of waste containers for Gamma radiation. The suite consists of a variety of pieces of equipment: ANTECH ANTCart, ANTECH Portable Drum Turntable, ANTECH Remote Battery Boxes

Active-Passive Drum Monitors (Differential Die Away), N2240 Series
Exempt waste & VLLW, ILW & high activity waste, LLW & greater than Class C waste, Neutron, Neutron Waste Assay, Plutonium & Uranium waste, TRU waste & ILW
The ANTECH N2240 Series are enhanced efficiency active-passive neutron counters for the measurement of plutonium and uranium in nuclear waste.

Active-Passive Neutron Crate Counter (Differential Die Away), N2940-2552
Exempt waste & VLLW, ILW & high activity waste, LLW & greater than Class C waste, Neutron, Plutonium & Uranium waste, TRU waste & ILW
The ANTECH N2940-2552 Active-Passive Crate Counter is an enhanced efficiency active/passive neutron counter designed for the measurement of plutonium and uranium in nuclear wastes contained in a variety of crates and waste boxes.

High Efficiency Passive Neutron Drum Monitor, N2223-220
ILW & high activity waste, LLW & greater than Class C waste, Neutron, Neutron Waste Assay
The ANTECH N2223-220 High Efficiency Passive Neutron Drum Monitor a high detection efficiency measurement system for the determination of plutonium mass in intermediate, transuranic or low level waste using passive neutron total coincidence or multiplicity counting, with a high detection efficiency.

Low Level Waste Segregation and Sentencing System (QED), G3400-220
Exempt waste & VLLW, Gamma, Gamma ray Waste Assay, LLW & greater than Class C waste, Plutonium & Uranium waste
The G3400-220 Low Level Waste Segregation and Sentencing System is designed to assist radioactive waste generators and assay specialists with the task of identifying, quantifying, and sorting radioactive wastes.

Passive Neutron Crate Counter, N2920-2550
Exempt waste & VLLW, ILW & high activity waste, LLW & greater than Class C waste, Neutron, Plutonium & Uranium waste, TRU waste & ILW
The N2920-2550 Passive Neutron Crate Counter is used for the determination of the Pu-240 mass in transuranic (TRU) waste transport containers.

Passive Neutron Drum Monitor, N2221-220
ILW & high activity waste, LLW & greater than Class C waste, Neutron, Neutron Waste Assay
The ANTECH N2221-220 Passive Neutron Drum Monitor is a comprehensive measurement system for the determination of plutonium mass in intermediate, transuranic or low level waste using passive neutron total coincidence or multiplicity counting.

RadSearch: Radioactivity and Decommissioning Monitor, G3050
Environmental Monitoring, Gamma, Gamma ray Waste Assay, Homeland Security, ILW & high activity waste, LLW & greater than Class C waste, Plutonium & Uranium waste, Radiation Detection, Remote handled waste, Special Measurement Applications, TRU waste & ILW
RadSearch is a device for measuring and quantifying radiation in the environment. It is particularly applicable to decommissioning and nuclear cleanup activities.

Segmented Gamma Scanner, G3200-340
Gamma, Gamma ray Waste Assay, ILW & high activity waste, LLW & greater than Class C waste, Plutonium & Uranium waste, TRU waste & ILW
The ANTECH Model G3200-340 Segmented Gamma ray Scanner (SGS) provides a non-destructive method of measuring the radionuclide content of waste, typically of Low Level Waste (LLW).

Segregated Waste Clearance Monitors for free release (Bag Monitor), G3301 Series
Environmental Monitoring, Exempt waste & VLLW, Gamma, LLW & greater than Class C waste
The ANTECH G3301 Series Segregated Waste Clearance Monitor quantifies and segregates gamma-ray emitting radioactive waste. The system detects gamma radiation in lightweight and low density bags and boxes.

Shielded Segmented Gamma Scanner, G3280-220
Exempt waste & VLLW, Gamma, Gamma ray Waste Assay, ILW & high activity waste, LLW & greater than Class C waste, TRU waste & ILW
The ANTECH Model G3280-220 Shielded Segmented Gamma Scanner (SSGS) is designed to measure low level radioactive waste arising from industrial, medical and nuclear power industries at very low detection levels.

Small Quantity Gross Gamma Soil Measurement System, G3101-0100
Environmental Monitoring, Exempt waste & VLLW, Gamma, Gamma ray Waste Assay, ILW & high activity waste, LLW & greater than Class C waste
This highly portable system consists of two wheel mounted sample trays that can inserted into a portable measurement (docking) station for the measurement of potentially contaminated soil.

Soil Measuring and Segregation System, G3107-1000
Environmental Monitoring, Exempt waste & VLLW, Gamma, Gamma ray Waste Assay, LLW & greater than Class C waste
The ANTECH Model G3107-1000 Soil Measuring and Segregation System measures and segregates soil with radiological contamination from uncontaminated soil.

Tomographic Gamma Scanner for cans and small objects, G3810
Exempt waste & VLLW, Gamma, Gamma ray Waste Assay, ILW & high activity waste, LLW & greater than Class C waste, Plutonium & Uranium waste, TRU waste & ILW
The ANTECH G3810 Tomographic Gamma Scanner for cans and small objects combines the functions of plutonium isotopic ratio analysis and tomographic gamma scanning in a single automated instrument.

Tomographic Gamma Scanner, G3850
Exempt waste & VLLW, Gamma, Gamma ray Waste Assay, ILW & high activity waste, LLW & greater than Class C waste, Plutonium & Uranium waste, TRU waste & ILW
The G3850 Tomographic Gamma Scanner (TGS) uses transmission corrected, single photon emission computerised axial tomography to determine the spatial distribution and quantity of radionuclides in a drum or can.

Universal Multi-Detector Counting System, B3001-600
Combined, Environmental Monitoring, Exempt waste & VLLW, Gamma, Gamma ray Waste Assay, LLW & greater than Class C waste, Special Measurement Applications
The B3001-600 Universal Multi-Detector Counting System (UMDCS) is a self-contained electronic module designed to be used with various radioactive analysis systems employing both gamma ray and neutron detectors. It can accommodate pulse outputs from plastic scintillators, sodium iodide detectors or ³He neutron detectors.

Universal Surface Dose Drum Monitor, G3030
Gamma, Gamma ray Waste Assay, ILW & high activity waste, LLW & greater than Class C waste
The ANTECH G3030 Universal Surface Dose Drum Monitor reproducibly measures the surface dose rate of large numbers of steel drums containing radioactive waste.

Wide Range Segmented/Tomographic Gamma Scanner, G3250-3850-320
Exempt waste & VLLW, Gamma, Gamma ray Waste Assay, ILW & high activity waste, LLW & greater than Class C waste, Plutonium & Uranium waste, TRU waste & ILW
The ANTECH G3250-3850-320 Wide Range Segmented/Tomographic Gamma Scanner (WR-SGS/TGS) builds on the segmented gamma scanning technique to measure the radionuclide content of waste drums.