Plutonium & Uranium waste
ANTECH provides a range of instruments for uranium and plutonium waste assay. These are based on a range of technologies, including gamma ray measurement, neutron measurement and calorimetry. In addition, ANTECH provides gamma ray instruments for determining the ratio of plutonium isotopes, which are used with neutron and calorimetry assay methods.

03 Wide Range Segmented Gamma Scanner, G3250-220
Exempt waste & VLLW, Gamma, Gamma ray Waste Assay, ILW & high activity waste, LLW & greater than Class C waste, Plutonium & Uranium waste, TRU waste & ILW
The ANTECH G3250-220 Wide Range Segmented Gamma Scanner (WR-SGS) builds on the segmented gamma scanning technique to measure the radionuclide content of waste drums.

04 Universal Neutron Counter, N2000 Series
Neutron, Neutron Waste Assay, Plutonium & Uranium waste, Safeguards, TRU waste & ILW
The ANTECH Universal Neutron Counter N2000 has been designed to provide a state of the art neutron counting capability for nuclear safeguards, waste assay and accounting measurements for special nuclear materials.

Active Well Coincidence Counter, N2442
Materials Inventory, Neutron, Neutron Waste Assay, Plutonium & Uranium waste, Safeguards, Safeguards
The ANTECH Model N2442 Active Well Coincidence Counter (AWCC) is a transportable high efficiency neutron counter for the measurement of plutonium and uranium.

Active-Passive Drum Monitors (Differential Die Away), N2240 Series
Exempt waste & VLLW, ILW & high activity waste, LLW & greater than Class C waste, Neutron, Neutron Waste Assay, Plutonium & Uranium waste, TRU waste & ILW
The ANTECH N2240 Series are enhanced efficiency active-passive neutron counters for the measurement of plutonium and uranium in nuclear waste.

Active-Passive Neutron Crate Counter (Differential Die Away), N2940-2552
Exempt waste & VLLW, ILW & high activity waste, LLW & greater than Class C waste, Neutron, Plutonium & Uranium waste, TRU waste & ILW
The ANTECH N2940-2552 Active-Passive Crate Counter is an enhanced efficiency active/passive neutron counter designed for the measurement of plutonium and uranium in nuclear wastes contained in a variety of crates and waste boxes.

Combined Isotopic and Plutonium Scrap Multiplicity Monitor, B2308
Combined, Combined Waste Assay, Integrated Measurement, Plutonium & Uranium waste, Safeguards, Safeguards, TRU waste & ILW
The ANTECH B2308 Combined Isotopic and Plutonium Scrap Multiplicity Counter for cans quickly and accurately determines the plutonium content of Special Nuclear Materials (SNM), scrap and residues.

De-Randomising Mixer Buffer Counter, N1081
ILW & high activity waste, Neutron, Neutron Waste Assay, Plutonium & Uranium waste, Safeguards, Safeguards, TRU waste & ILW
The ANTECH N1081 De-Randomising Mixer Buffer provides useful test and diagnostic information for multi-counting chain neutron detectors by determining independent software readable neutron totals counting for each input counting chain and statistical data analysis for each counting channel.

Drum Decommissioning Piece Monitor, N2024-220
Materials Inventory, Neutron, Neutron Waste Assay, Plutonium & Uranium waste, TRU waste & ILW
The N2024-220 Decommissioning Piece Monitor is a transportable efficient neutron assay instrument for the monitoring of intermediate level Plutonium Contaminated Material (PCM) waste arising from decommissioning operations.

High Sensitivity Large Sample In-Line (Glove Box) Calorimeter, CA503-260
Calorimetry, Calorimetry Waste Assay, Plutonium & Uranium waste, Safeguards
The design of the demountable CA503-260 High Sensitivity In-Line (Glove Box) Calorimeter is based around a sample well that maintains glove box integrity.

High-Level Neutron Coincidence Counter, N2018
Neutron, Plutonium & Uranium waste, Safeguards, Safeguards
The ANTECH Model N2018 High-Level Neutron Coincidence Counter is a medium efficiency passive neutron counter for measuring the spontaneous and induced fission from the even isotopes of plutonium bearing samples, including PuO2, mixed oxides, metal carbides, solution and scrap.

Low Level Waste Segregation and Sentencing System (QED), G3400-220
Exempt waste & VLLW, Gamma, Gamma ray Waste Assay, LLW & greater than Class C waste, Plutonium & Uranium waste
The G3400-220 Low Level Waste Segregation and Sentencing System is designed to assist radioactive waste generators and assay specialists with the task of identifying, quantifying, and sorting radioactive wastes.

Neutron Coincidence Collar, N2023-M
Materials Inventory, Neutron, Plutonium & Uranium waste, Safeguards, Safeguards
The ANTECH N2023-M Neutron Coincidence Collar (NCC), similar in specification to the ANTECH N2044 Neutron Coincidence Collar (NCC), is used by safeguards inspectors to verify the fissile material content of fresh BWR nuclear fuel assemblies.

Neutron Coincidence Collar, N2044
Materials Inventory, Neutron, Plutonium & Uranium waste, Safeguards, Safeguards
The ANTECH N2044 Neutron Coincidence Collar (NCC) is used by safeguards inspectors to verify the fissile material content of fresh nuclear fuel assemblies.

Neutron Coincidence Collar, N2071
Materials Inventory, Neutron, Plutonium & Uranium waste, Safeguards, Safeguards
The ANTECH N2071 Neutron Coincidence Collar is used by international safeguards inspectors to verify the fissile material content of fresh nuclear fuel assemblies.

Neutron Time Correlation Analyser (TCA), N1003
ILW & high activity waste, Neutron, Neutron Waste Assay, Plutonium & Uranium waste, Safeguards, Safeguards, TRU waste & ILW
The ANTECH N1003 Series Neutron Time Correlation Analyser (TCA) is a comprehensive multiplicity counter for the passive neutron analysis of plutonium.

Passive Neutron Crate Counter, N2920-2550
Exempt waste & VLLW, ILW & high activity waste, LLW & greater than Class C waste, Neutron, Plutonium & Uranium waste, TRU waste & ILW
The N2920-2550 Passive Neutron Crate Counter is used for the determination of the Pu-240 mass in transuranic (TRU) waste transport containers.

Passive Neutron Slab Counter & Curium Monitor, N2004
Neutron, Neutron Waste Assay, Plutonium & Uranium waste, Safeguards
The N2004 Passive Neutron Slab Counter & Curium Monitor is a simple, non-quantitative neutron slab counter for the detection of curium contamination in waste drums, boxes or crates.

Plutonium Scrap Multiplicity Counter, N2098
Materials Inventory, Neutron, Neutron Waste Assay, Plutonium & Uranium waste, Safeguards, Safeguards
The ANTECH Model N2098 Plutonium Scrap Multiplicity Counter is a high efficiency passive neutron counter for measuring the multiplicity of neutron emissions from the spontaneous fission and induced fission of plutonium bearing samples of scrap and residues.

Precision Twin Cell Sample Calorimeters, CHF400 Series
Calorimetry, Calorimetry Waste Assay, Plutonium & Uranium waste, Safeguards, Safeguards
The ANTECH CHF400 Series Precision Twin Cell Sample Calorimeters feature a thermostatically controlled calorimeter body that houses two identical cylindrical or rectangular cells, one “sample” and one “reference”. Both cells have the same construction and the same heat transfer properties. The CHF400 Series are available in a variety of volume sizes.

RadSearch: Radioactivity and Decommissioning Monitor, G3050
Environmental Monitoring, Gamma, Gamma ray Waste Assay, Homeland Security, ILW & high activity waste, LLW & greater than Class C waste, Plutonium & Uranium waste, Radiation Detection, Remote handled waste, Special Measurement Applications, TRU waste & ILW
RadSearch is a device for measuring and quantifying radiation in the environment. It is particularly applicable to decommissioning and nuclear cleanup activities.

Sample Decommissioning Piece Monitor, N2072
Neutron, Neutron Waste Assay, Plutonium & Uranium waste, TRU waste & ILW
The N2072 Passive Neutron Decommissioning Piece Monitor is a high efficiency passive neutron counter designed for the measurement of plutonium contaminated size reduced pieces arising from the decommissioning of nuclear plant and equipment.

Segmented Gamma Scanner, G3200-340
Gamma, Gamma ray Waste Assay, ILW & high activity waste, LLW & greater than Class C waste, Plutonium & Uranium waste, TRU waste & ILW
The ANTECH Model G3200-340 Segmented Gamma ray Scanner (SGS) provides a non-destructive method of measuring the radionuclide content of waste, typically of Low Level Waste (LLW).

Tomographic Gamma Scanner for cans and small objects, G3810
Exempt waste & VLLW, Gamma, Gamma ray Waste Assay, ILW & high activity waste, LLW & greater than Class C waste, Plutonium & Uranium waste, TRU waste & ILW
The ANTECH G3810 Tomographic Gamma Scanner for cans and small objects combines the functions of plutonium isotopic ratio analysis and tomographic gamma scanning in a single automated instrument.

Tomographic Gamma Scanner, G3850
Exempt waste & VLLW, Gamma, Gamma ray Waste Assay, ILW & high activity waste, LLW & greater than Class C waste, Plutonium & Uranium waste, TRU waste & ILW
The G3850 Tomographic Gamma Scanner (TGS) uses transmission corrected, single photon emission computerised axial tomography to determine the spatial distribution and quantity of radionuclides in a drum or can.

Wide Range Segmented/Tomographic Gamma Scanner, G3250-3850-320
Exempt waste & VLLW, Gamma, Gamma ray Waste Assay, ILW & high activity waste, LLW & greater than Class C waste, Plutonium & Uranium waste, TRU waste & ILW
The ANTECH G3250-3850-320 Wide Range Segmented/Tomographic Gamma Scanner (WR-SGS/TGS) builds on the segmented gamma scanning technique to measure the radionuclide content of waste drums.