Products
View products by technology, application or solution.

01 Low Resolution Drum Gamma Scanner, G3410-200
Environmental Monitoring, Exempt waste & VLLW, Gamma, Gamma ray Waste Assay, LLW & greater than Class C waste
The ANTECH Model G3410-200 LRDGS is a transportable Low Resolution Gamma Scanner for the characterisation and measurement of 200 L drums of waste.

02 EMBASSY (Excavator Mounted Bucket Assay System) G3102-4216
Environmental Monitoring, Exempt waste & VLLW, Gamma, Gamma ray Waste Assay, LLW & greater than Class C waste, Mobile In-Situ Measurement Laboratories, Radiation Detection, Radioactive Waste Measurement, Radioactive Waste Measurement
The ANTECH excavator mounted bucket assay system (EMBASSY) model G3102-4216 is a system designed to measure the radioactive contents of an excavator bucket.

03 Wide Range Segmented Gamma Scanner, G3250-220
Exempt waste & VLLW, Gamma, Gamma ray Waste Assay, ILW & high activity waste, LLW & greater than Class C waste, Plutonium & Uranium waste, TRU waste & ILW
The ANTECH G3250-220 Wide Range Segmented Gamma Scanner (WR-SGS) builds on the segmented gamma scanning technique to measure the radionuclide content of waste drums.

04 Universal Neutron Counter, N2000 Series
Neutron, Neutron Waste Assay, Plutonium & Uranium waste, Safeguards, TRU waste & ILW
The ANTECH Universal Neutron Counter N2000 has been designed to provide a state of the art neutron counting capability for nuclear safeguards, waste assay and accounting measurements for special nuclear materials.

05 Automated Gamma Spectroscopy System (AGSS), G3010
Environmental Monitoring, Gamma, Measurement Automation, Radiation Detection, Radioactive Sample Counting & Measurement
The ANTECH model G3010 Automated Gamma Spectroscopy System (AGSS) or automated sample changer is an effective solution for performing automated, unattended, high-resolution gamma spectroscopy (HRGS) measurements and analysis of bulk samples in a variety of sizes and types of Marinelli beakers.

06 CHARMS (Characterisation Assay & Radiation Monitoring Station) G3650
Environmental Monitoring, Radioactive Waste Measurement, Radioactive Waste Measurement
CHARMS is a mobile assay and measuring system for making laboratory quality measurements of drums, waste bags and other waste objects in the field.

07 In-Situ Mobile Assay of Gamma Equipment (IMAGE)
Gamma, Gamma ray Waste Assay, ILW & high activity waste, LLW & greater than Class C waste, Mobile In-Situ Measurement Laboratories
The ANTECH IMAGE is a suite of measurement service equipment used for portable assay of all types of waste containers for Gamma radiation. The suite consists of a variety of pieces of equipment: ANTECH ANTCart, ANTECH Portable Drum Turntable, ANTECH Remote Battery Boxes

08 ANTCart
Environmental Monitoring, Gamma, Gamma ray Waste Assay, Integrated Measurement, Materials Inventory, Mobile In-Situ Measurement Laboratories, Radiation Detection, Radioactive Sample Counting & Measurement, Radioactive Waste Measurement, Radioactive Waste Measurement
ANTCart is a rugged, mobile detector platform designed to position and mount High Purity Germanium (HPGe) and other detectors for measurements of drums, boxes and large containers.

09 Network Neutron Counter (NNC) N2000-2
The ANTECH Network Neutron Counter, Model N2000-2 combines Total Neutron Counting, Shift Register Coincidence Counting and Multiplicity Counting in a portable package to provide a state of the art instrument. The N2000-2 offers the benefits of immediate measurement results provided by the Instruments real-time software, displayed on the front panel touch screen. The 512 […]

Active Well Coincidence Counter, N2442
Materials Inventory, Neutron, Neutron Waste Assay, Plutonium & Uranium waste, Safeguards, Safeguards
The ANTECH Model N2442 Active Well Coincidence Counter (AWCC) is a transportable high efficiency neutron counter for the measurement of plutonium and uranium.

Active-Passive Drum Monitors (Differential Die Away), N2240 Series
Exempt waste & VLLW, ILW & high activity waste, LLW & greater than Class C waste, Neutron, Neutron Waste Assay, Plutonium & Uranium waste, TRU waste & ILW
The ANTECH N2240 Series are enhanced efficiency active-passive neutron counters for the measurement of plutonium and uranium in nuclear waste.

Active-Passive Neutron Crate Counter (Differential Die Away), N2940-2552
Exempt waste & VLLW, ILW & high activity waste, LLW & greater than Class C waste, Neutron, Plutonium & Uranium waste, TRU waste & ILW
The ANTECH N2940-2552 Active-Passive Crate Counter is an enhanced efficiency active/passive neutron counter designed for the measurement of plutonium and uranium in nuclear wastes contained in a variety of crates and waste boxes.

Baggage and Air Freight Contamination Portal Monitor, G5321-400
Environmental Monitoring, Gamma, Radiation Detection
The ANTECH G5321-400 Baggage and Air Freight Contamination Portal Monitor is designed to detect gamma-ray emitting radioactive materials in and surface contamination on baggage and air freight containers.

Baggage/Air Freight Homeland Security Portal Monitor, B5521-420
Combined, Homeland Security, Radiation Detection
The ANTECH B5521-420 Baggage and Air Freight Homeland Security Portal Monitor is designed to detect radioactive materials in baggage and air freight containers. It has both gamma ray and neutron detection capability.

Calorimeter Pre-heater, CP271-0442
The ANTECH Model CP271-0442 calorimeter pre-heater uses the temperature control technology developed for the ANTECH CP Series calorimeters.

Combined Isotopic and Plutonium Scrap Multiplicity Monitor, B2308
Combined, Combined Waste Assay, Integrated Measurement, Plutonium & Uranium waste, Safeguards, Safeguards, TRU waste & ILW
The ANTECH B2308 Combined Isotopic and Plutonium Scrap Multiplicity Counter for cans quickly and accurately determines the plutonium content of Special Nuclear Materials (SNM), scrap and residues.

Conveyor based drum handling systems
ANTECH designs, builds and supplies a variety of conveyor systems in association with its waste assay equipment. These conveyors are used to load and unload drums into waste assay instruments, to buffer drums waiting for a measurement or assay, and to provide a buffer for drums that have been measured.

De-Randomising Mixer Buffer Counter, N1081
ILW & high activity waste, Neutron, Neutron Waste Assay, Plutonium & Uranium waste, Safeguards, Safeguards, TRU waste & ILW
The ANTECH N1081 De-Randomising Mixer Buffer provides useful test and diagnostic information for multi-counting chain neutron detectors by determining independent software readable neutron totals counting for each input counting chain and statistical data analysis for each counting channel.

Drum Decommissioning Piece Monitor, N2024-220
Materials Inventory, Neutron, Neutron Waste Assay, Plutonium & Uranium waste, TRU waste & ILW
The N2024-220 Decommissioning Piece Monitor is a transportable efficient neutron assay instrument for the monitoring of intermediate level Plutonium Contaminated Material (PCM) waste arising from decommissioning operations.

Far Field Gamma Monitor for drums and small objects, G3620-340
Environmental Monitoring, Gamma, Gamma ray Waste Assay, Remote handled waste
The ANTECH Model G3620-340 Far Field Gamma Monitor is the basic assay system for drums and small objects using far field gamma ray measurement geometry.

Far Field Gamma Monitor, G3601
Environmental Monitoring, Gamma, Gamma ray Waste Assay, Remote handled waste
The Model G3601 Far Field Gamma Monitor is a generic design that can be supplied in a number of different configurations.

Fork Detectors (EURATOM) B2104 Series
Combined, Safeguards, Safeguards
ANTECH B2104 Series Fork Detectors are routinely used as inspection tools, for safeguards purposes, and to conduct non-destructive measurements to determine the radiation from reactor pond fuel rod assemblies while stored underwater.

Fork Detectors (IAEA) B2102 Series
Combined, Safeguards, Safeguards
ANTECH B2102 Series Fork Detectors are routinely used as inspection tools, for safeguards purposes, and to conduct non-destructive measurements to determine the radiation from reactor pond fuel rod assemblies while stored underwater.

Fuel Element Debris Monitor, G3651
Gamma, Gamma ray Waste Assay, ILW & high activity waste, Remote handled waste
The ANTECH Model G3651 Fuel Element Debris (FED) Monitor is a heavily shielded and collimated far field measurement instrument originally designed for the measurement of highly radioactive fuel element components and debris from UK MAGNOX reactors.

High Efficiency Passive Neutron Drum Monitor, N2223-220
ILW & high activity waste, LLW & greater than Class C waste, Neutron, Neutron Waste Assay
The ANTECH N2223-220 High Efficiency Passive Neutron Drum Monitor a high detection efficiency measurement system for the determination of plutonium mass in intermediate, transuranic or low level waste using passive neutron total coincidence or multiplicity counting, with a high detection efficiency.