Products
View products by technology, application or solution.

High Sensitivity Large Sample Calorimeter, CP264-0420
Calorimetry, Calorimetry Waste Assay, Safeguards, TRU waste & ILW
The ANTECH CP264-0420 High Sensitivity Large Sample Calorimeter is applicable to a wide range of plutonium measurement requirements.

High Sensitivity Large Sample Calorimeter, CV364-1490
Calorimetry, Calorimetry Waste Assay, Safeguards, Safeguards, TRU waste & ILW
The CV364-1490 Calorimeter is transportable without compromising measurement accuracy so that it may be moved to the measurement site.

High Sensitivity Large Sample In-Line (Glove Box) Calorimeter, CA503-260
Calorimetry, Calorimetry Waste Assay, Plutonium & Uranium waste, Safeguards
The design of the demountable CA503-260 High Sensitivity In-Line (Glove Box) Calorimeter is based around a sample well that maintains glove box integrity.

High-Level Neutron Coincidence Counter, N2018
Neutron, Plutonium & Uranium waste, Safeguards, Safeguards
The ANTECH Model N2018 High-Level Neutron Coincidence Counter is a medium efficiency passive neutron counter for measuring the spontaneous and induced fission from the even isotopes of plutonium bearing samples, including PuO2, mixed oxides, metal carbides, solution and scrap.

Low Level Waste Segregation and Sentencing System (QED), G3400-220
Exempt waste & VLLW, Gamma, Gamma ray Waste Assay, LLW & greater than Class C waste, Plutonium & Uranium waste
The G3400-220 Low Level Waste Segregation and Sentencing System is designed to assist radioactive waste generators and assay specialists with the task of identifying, quantifying, and sorting radioactive wastes.

Neutron Coincidence Collar, N2023-M
Materials Inventory, Neutron, Plutonium & Uranium waste, Safeguards, Safeguards
The ANTECH N2023-M Neutron Coincidence Collar (NCC), similar in specification to the ANTECH N2044 Neutron Coincidence Collar (NCC), is used by safeguards inspectors to verify the fissile material content of fresh BWR nuclear fuel assemblies.

Neutron Coincidence Collar, N2044
Materials Inventory, Neutron, Plutonium & Uranium waste, Safeguards, Safeguards
The ANTECH N2044 Neutron Coincidence Collar (NCC) is used by safeguards inspectors to verify the fissile material content of fresh nuclear fuel assemblies.

Neutron Coincidence Collar, N2071
Materials Inventory, Neutron, Plutonium & Uranium waste, Safeguards, Safeguards
The ANTECH N2071 Neutron Coincidence Collar is used by international safeguards inspectors to verify the fissile material content of fresh nuclear fuel assemblies.

Neutron Time Correlation Analyser (TCA), N1003
ILW & high activity waste, Neutron, Neutron Waste Assay, Plutonium & Uranium waste, Safeguards, Safeguards, TRU waste & ILW
The ANTECH N1003 Series Neutron Time Correlation Analyser (TCA) is a comprehensive multiplicity counter for the passive neutron analysis of plutonium.

Neutron Under Water Coincidence Counter (EURATOM), N2108
Integrated Measurement, Neutron, Safeguards, Safeguards
N2108 Neutron Under Water Coincidence Counters (UWCCs) are routinely used as inspection tools, for safeguards purposes and to conduct non-destructive measurements to determine the radiation from reactor pond fuel rod assemblies whilst stored underwater.

Neutron Under Water Coincidence Counter (IAEA), N2106
Integrated Measurement, Neutron, Safeguards, Safeguards
N2106 Neutron Under Water Coincidence Counters are routinely used as inspection tools, for safeguards purposes and to conduct non-destructive measurements to determine the radiation from reactor pond fuel rod assemblies whilst stored underwater.

Package Contamination Portal Monitor, G5311-200
Environmental Monitoring, Gamma, Radiation Detection
The ANTECH G5311-200 Package Portal Monitor is designed to detect radioactive contamination in components or small packages.

Passive Neutron and Gamma ray Multiplicity Drum Monitor, B2307-220
Combined, Combined Waste Assay
The ANTECH Model B2307-220 Passive Neutron and Gamma ray Drum Monitor is an integrated system based on combining the N2221-220 Passive Neutron Drum Monitor with a Plutonium/Uranium isotopic gamma ray scanning instrument such as the G3501.

Passive Neutron Crate Counter, N2920-2550
Exempt waste & VLLW, ILW & high activity waste, LLW & greater than Class C waste, Neutron, Plutonium & Uranium waste, TRU waste & ILW
The N2920-2550 Passive Neutron Crate Counter is used for the determination of the Pu-240 mass in transuranic (TRU) waste transport containers.

Passive Neutron Drum Monitor, N2221-220
ILW & high activity waste, LLW & greater than Class C waste, Neutron, Neutron Waste Assay
The ANTECH N2221-220 Passive Neutron Drum Monitor is a comprehensive measurement system for the determination of plutonium mass in intermediate, transuranic or low level waste using passive neutron total coincidence or multiplicity counting.

Passive Neutron Slab Counter & Curium Monitor, N2004
Neutron, Neutron Waste Assay, Plutonium & Uranium waste, Safeguards
The N2004 Passive Neutron Slab Counter & Curium Monitor is a simple, non-quantitative neutron slab counter for the detection of curium contamination in waste drums, boxes or crates.

Pedestrian Contamination Portal Monitor, G5332-400
Environmental Monitoring, Gamma, Radiation Detection
The ANTECH G5332-400 Contamination Pedestrian Portal Monitor is designed to detect gamma ray emitting substances, including materials contaminated with fission and activation products such as Cs-137 and Co-60.

Pedestrian Homeland Security Portal Monitor, B5532-440
Combined, Homeland Security, Radiation Detection
The ANTECH B5532-440 Pedestrian Homeland Security Portal Monitor is designed to detect radioactive materials. It has both gamma ray and neutron detection capacity.

Plutonium Isotopic Spectrometer, G3501
Gamma, Gamma ray Waste Assay, Integrated Measurement, Materials Inventory, Safeguards, Safeguards, Special Measurement Applications
The ANTECH G3501 Plutonium Isotopic Ratio Spectrometer is a comprehensive measurement system for the determination of plutonium isotopic ratios.

Plutonium Scrap Multiplicity Counter, N2098
Materials Inventory, Neutron, Neutron Waste Assay, Plutonium & Uranium waste, Safeguards, Safeguards
The ANTECH Model N2098 Plutonium Scrap Multiplicity Counter is a high efficiency passive neutron counter for measuring the multiplicity of neutron emissions from the spontaneous fission and induced fission of plutonium bearing samples of scrap and residues.

Precision Twin Cell Sample Calorimeters, CHF400 Series
Calorimetry, Calorimetry Waste Assay, Plutonium & Uranium waste, Safeguards, Safeguards
The ANTECH CHF400 Series Precision Twin Cell Sample Calorimeters feature a thermostatically controlled calorimeter body that houses two identical cylindrical or rectangular cells, one “sample” and one “reference”. Both cells have the same construction and the same heat transfer properties. The CHF400 Series are available in a variety of volume sizes.

RadSearch: Radioactivity and Decommissioning Monitor, G3050
Environmental Monitoring, Gamma, Gamma ray Waste Assay, Homeland Security, ILW & high activity waste, LLW & greater than Class C waste, Plutonium & Uranium waste, Radiation Detection, Remote handled waste, Special Measurement Applications, TRU waste & ILW
RadSearch is a device for measuring and quantifying radiation in the environment. It is particularly applicable to decommissioning and nuclear cleanup activities.

Sample Decommissioning Piece Monitor, N2072
Neutron, Neutron Waste Assay, Plutonium & Uranium waste, TRU waste & ILW
The N2072 Passive Neutron Decommissioning Piece Monitor is a high efficiency passive neutron counter designed for the measurement of plutonium contaminated size reduced pieces arising from the decommissioning of nuclear plant and equipment.

Segmented Gamma Scanner, G3200-340
Gamma, Gamma ray Waste Assay, ILW & high activity waste, LLW & greater than Class C waste, Plutonium & Uranium waste, TRU waste & ILW
The ANTECH Model G3200-340 Segmented Gamma ray Scanner (SGS) provides a non-destructive method of measuring the radionuclide content of waste, typically of Low Level Waste (LLW).

Segregated Waste Clearance Monitors for free release (Bag Monitor), G3301 Series
Environmental Monitoring, Exempt waste & VLLW, Gamma, LLW & greater than Class C waste
The ANTECH G3301 Series Segregated Waste Clearance Monitor quantifies and segregates gamma-ray emitting radioactive waste. The system detects gamma radiation in lightweight and low density bags and boxes.